Culligan offers a full range of high quality Feeders, Control Instruments, and Electronic Timers.adaptable to any application or flow rate requirement. For further information, either scroll down the page or click on the category you are interested in or click here to contact a Culligan professional.

Feeders

Culligan automatic feeders are electronic and offer high injection precision combined with extremely reliable operation. Fitted with electromagnets, they allow the feeding rate to be adjusted by varying the frequency.

The range includes constant feed rate models, in which the feeder flow rate remains constant after the initial setting, and self-adjusting models, in which, after the initial setting, the feeding rate is controlled on the basis of variations in flow rate or other pre-set parameters (pH, residual Chlorine, etc.).

Easy Feeder
Constant Feed Rate Feeder

Of simple construction and compact in size, it provides an economical solution to the most common requirement. The body is in corrosion-resistant plastic. It is supplied complete with bracket for vertical mounting. Available in just one model, for low flow rates.

Basic, Prop and Logic Feeder

Basic, Prop and Logic series models feature:

  • three different maximum feed rate capabilities for each series
  • tough, reliable construction
  • aluminium body, with triple anti-corrosion treatment
  • parts in contact with the liquids for injection in Polypropylene,Viton and Teflon
  • electronic circuit which cuts out the pump in case of minimum level signal
  • supplied for horizontal installation, but vertical installation is possible with just a few simple operations
  • selector switch for optimising feeding even at minimum flow rates.

These three series have the following special features:

Basic Feeder - Constant feed rate feeder
Works on the basis of a simple on-off command received from the system (electric float-switch, pump, instrument, etc.).

Prop Feeder - Self-adjusting feeder
The feed rate is automatically adjusted on the basis of pulses received from external meters (available as accessories). Operation with on-off control is available on request.

Logic Feeder - Self-adjusting feeder
The feed rate is controlled by a 4/20 mA DC signal received from instruments of various type. Complete with display, keyboard and microprocessor for setting and functional checks. Operation with on-off control is possible.

Click here for Feeder Technical Specifications

Back to top

Control Instruments

The water used in industrial processes requires accurate, prompt control of the fundamental values which define its quality. The main parameters concerned are temperature, pH, conductivity, oxidation-reduction potential (Redox) and residual Chlorine.

For each of these needs, Culligan offers a complete range of measurement instruments to complement its water treatment systems.

pH-Meters

Model S595 - pH (for control panel)
Specifications

  • Standard measuring range: 0-14 pH
  • Indicator: digital, liquid crystal (LCD), 3½ digit, h=½"
  • Current output: 4-20 mA DC on load <700 Ohm
  • Protection degree: IP 44

Model WP 91E-pH (for wall mounting)
Specifications

  • Standard measuring range: 0-14 pH
  • Indicator: digital, liquid crystal (LCD), 3½ digit
  • Current output: 4-20 mA DC on max. load 500 Ohm
  • Protection degree: IP 65

Redox-Meters

Model S595-Rx (for control panel)
Specifications

  • Standard measuring range: 0-1000 mV
  • Indicator: digital, liquid crystal (LCD), 3½ digit, h=½"
  • Current output: 4-20 mA DC on load <700 Ohm
  • Protection degree: IP 44

Model WP 91E-Rx (for wall mounting)
Specifications

  • Standard measuring range: 0-1000 mV
  • Indicator: digital, liquid crystal (LCD), 3½ digit
  • Current output: 4-20 mA DC on max. load 500 Ohm
  • Protection degree: IP 65

Conductivity Meters

Model S595-C (for control panel)
Specifications

  • Standard measuring range: 0-19.99 µS; 0-199.9 µS; 0-1999 µS
  • Indicator: digital, liquid crystal (LCD), 3½ digit, h=½"
  • Reading accuracy: ± 2 digit
  • Current output: 4-20 mA DC on load <500 Ohm
  • Protection degree: IP 44

Model WP 91E-C1 (for wall mounting)
Specifications

  • Standard measuring range: 0-2 µS
  • Indicator: digital, liquid crystal (LCD), 3½ digit
  • Current output: 4-20 mA DC on max. load 500 Ohm
  • Protection degree: IP 65

Model WP 91E-C10 (for wall mounting)
Specifications

  • Standard measuring range: 0-20 µS
  • Indicator: digital, liquid crystal (LCD), 3½ digit
  • Current output: 4-20 mA DC on max. load 500 Ohm
  • Protection degree: IP 65

Model WP 91E-C100 (for wall mounting)
Specifications

  • Standard measuring range: 0-200 µS
  • Indicator: digital, liquid crystal (LCD), 3½ digit
  • Current output: 4-20 mA DC on max. load 500 Ohm
  • Protection degree: IP 65

Model WP 91E-C1000 (for wall mounting)
Specifications

  • Standard measuring range: 0-2000 µS
  • Indicator: digital, liquid crystal (LCD), 3½ digit
  • Current output: 4-20 mA DC on max. load 500 Ohm
  • Protection degree: IP 65

Residual Chlorine Meters

Model S595 - C1 (for control panel)
Specifications

  • Standard measuring range: 1/2/5/10 ppm free Cl2
  • Indicator: digital 3½ digit, LCD ½"
  • Current output: 4-20 mA DC on max. load 700 Ohm
  • Protection degree: IP 44

Model WP91 C1 (for wall mounting)
Specifications

  • Standard measuring range: 1/2/5/10 ppm free Cl2
  • Indicator: digital 3½ digit, LCD ½"
  • Current output: 4-20 mA DC on max. load 500 Ohm
  • Protection degree: IP 65

Thermometers

Model S595T (for control panel)
Specifications

  • Standard measuring range: 0-100&#deg;C
  • Indicator: digital, liquid crystal (LCD), 3½ digit, h=½"
  • Current output: 4-20 mA DC on load <300 Ohm
  • Protection degree: IP 44

Residual Hardness Analysers

Testomat Model F-BOB
Specifications

  • Measurements at regular intervals of 5-10-20 or 30 minutes
  • Pressure: 10 bar max.
  • Temperature: 45&#deg;C max.
  • Parts in contact with the water in corrosion proof material.

Analysers for Measurements and Automatic Control of pH and Redox

Waco Model (for wall mounting)
Specifications

  • pH section
  • Standard measuring range: 0-14 pH
  • Rx section
  • Standard measuring range: 0-1000 mV
  • Protection degree: IP 65


Back to top

Electronic Timers

Depending on requirements, equipment is controlled and operated by one of a range of timers:

  • PLF (Programmable Logic Function) Electronic Timer 2K Model: for individual equipment.
  • PLM (Multitask) Electronic Timer 2K Model: for equipment and systems requiring control of a number of functions.
  • PLC - HQW (High Quality Water) Electronic Timer: for systems for the production of water for haemodialysis, and in general where very high water quality is required.

The timers of all Culligan plants in the range (i.e. all except household systems) are supplied at 24 V - 50 Hz. An optional transformer is available.